Motors from 0.37kW to 375kW make up the vast majority (approximately 90%) of installed motor population and are covered by the standard IS 12615:2011. This fulfills the need of the manufacturers to design motor for a global market. This standard defines four efficiency classes for nominal frequency 50Hz.
Learn MoreMotors that fall witin the EI1 efficiency class have the following specifications: Output is 0.75kW to 355kW. Poles are 2, 4, 6, 8, 10 and 12. Speed range is from 500rpm to 3600rpm. RPM frequency is 50Hz or 60Hz. Temperature class is B class. Insulation class is class F. Protection technology used is IP55, IP56, IP65, IP66. IE2 - High Efficiency
Learn MoreMotor Power (kW) Motor Current (Amps) Frame Size. 0.37. 1. 71. 0.55. 1.5. 80.
Learn MoreLow voltage Industrial performance motors Sizes 63 to 400, 0.12 to 630 kW ABB reserves the right to change the design, technical specification and dimensions without prior notice.
Learn More4 Pole = 1400rpm · Amps at 400v - 10.81 · Frame Size - MS133S-4 · Rugged and Reliable · Lightweight aluminium Construction · Suitable for wet and dusty applications
Learn More4.1.2 Designs - Minimum Standardized Torque Values 26. 4.1.3 Characteristics of WEG Motors . A three-phase electric motor, 100 HP ( 75 kW ), IV poles,.
Learn More0.75 - 375 kW shall have a minimum efficiency class of IE3, Motors with frame size from 355 have feet integrated with the motor housing.
Learn MoreFrom 1 July motors between 0.75 kW and 1000 kW will be required to meet a minimum efficiency class of IE3, the group of smaller motors from 0.12 kW to 0.75 kW minimum IE2. From 1 July 2023, motors between 75 kW and 200 kW will be required to meet the even higher efficiency class of IE4. All the details are available here.
Learn MoreIn frame number 145, for example, the first two digits divided by the constant 4 is equal to the “D” dimension, 14 divided by 4 = 3½”. Similarly, the “D” dimension of a 213 frame motor is 5¼”, 21 divided by 4 = 5¼”. By NEMA definition, two—digit frame numbers are fractional frames even though 1 HP or larger motors may be built in them.
Learn MorekW 200 505 440 278 255 192 MOTOR RATING HP APPROX. F.L.C. AT LINE VOLTAGE MOTOR RATING HP APPROX. F.L.C. AT LINE VOLTAGE AC Motors - full load current tables (1450rpm approx.) (provided as a guide to the selection of suitable MEM control gear). The tables are based on motors of approximately 1450rpm of average efficiency and power factor.
Learn MoreAvailable in round frame and unique laminated square frames, Baldor-Reliance® DC motors offer performance and reliability in tough applications. Round frame DC motors utilize permanent magnet technology optimizing the commutator, brushes and inertia to assure the best performance possible. Wound field motors are designed with high-performance
Learn More